Products > Sound Measurement > Floor Impact Sound Measurement
Sound Insulation Measurment / Testing
Floor Impact Sound Measurement
Reverberation Time Measurement
Noise Measurement
@ @
Floor Impact-1 Floor Impact-2 Floor Impact-3 Floor Impact-4
Floor impact sound measurement is the measurement of a floorfs interceptive power. When a floor receives an impact or vibrations, these vibrations travel throughout the structure and are given off as solid borne transmission sounds. Our measurement process shows light weight impact sources such as high heel shoes and footsteps (tapping machine) as well as heavy weight impact sources such as a person jumping (bang machine).
In testing the performance of the structures and dampening measures in apartment buildings and hotels, floor impact sound measurement is absolutely necessary. AGK is winning the trust of customers with fast testing, analysis and reporting. We offer more than just testing, but also offer counter measures when necessary, fast spot-on advice, consulting, soundproofing and dampening design. We follow our customers needs all the way to construction.


Method of measuring floor impact sound

This measurement applies to JIS A1418 "Measurement of the floor impact sound interception performance in a building". The light floor impact source and the weight floor impact source are set up in the sound source room as shown in the figure below. Then, the floor is vibrated, and the sound level meter measures it by the receiving sound room plural point. The mean value of the receiving sound room energy is calculated and the floor impact sound performance is figured from the result of that measurement.